DAD LINK SF/UTP Cat.6 Outdoor Network Cable – 305 m of 23 AWG solid bare copper in a double PVC jacket with a UV-resistant black outer sheath, foil-screened and braided with tinned copper for outdoor and direct-sunlight runs.
Built for the parts of a network that live outside: building-to-building links, rooftop and pole-mounted access points, CCTV drops, car parks, and perimeter security. The outer sheath is sunlight-resistant — after 300 hours of exposure testing it retains at least 85% of its tensile strength and elongation, so it does not chalk and split the way standard indoor PVC does. The tinned copper braid resists corrosion where a bare aluminium braid would oxidise, and the twin PVC sheaths give the mechanical margin for conduit pulls and burial in duct.
Note: this is a PVC cable, UV-rated for outdoor use. For runs inside occupied buildings, fire regulations generally call for the LSZH version.
Key Specifications
- Category: Cat.6 (Class E), outdoor / UV resistant
- Standards: ISO/IEC 11801, ANSI/TIA-568.2-D
- Bandwidth: 250 MHz — 1 Gbps to 100 m
- Conductor: solid bare copper, 0.565 ± 0.005 mm (23 AWG)
- Insulation: HDPE, 1.12 ± 0.08 mm
- Inner screen: Mylar + Al/Mylar foil
- Outer screen: tinned copper braid, ≥ 30% coverage
- Inner sheath: PVC, 0.55 ± 0.1 mm
- Outer sheath: UV-resistant PVC (RoHS compliant), black, 0.55 ± 0.1 mm
- Outside diameter: 9.0 ± 0.5 mm
- Sunlight resistance: 300 h exposure — ≥ 85% tensile and elongation retained
- Tensile strength: ≥ 13.5 MPa · elongation ≥ 150%
- After ageing (100 °C, 7 days): ≥ 12.5 MPa · elongation ≥ 125%
- Impedance: 100 ± 15 Ω (1–250 MHz)
- DC resistance: ≤ 9.38 Ω/100 m · unbalance ≤ 5.0%
- Delay skew: ≤ 45 ns/100 m
- Cold bend: −20 ± 2 °C, 8× cable O.D., no visible cracks
- Length: 305 ± 1.5 m, drum on wooden tray · rip-cord included
Transmission Performance (per 100 m)
| Frequency | Return loss | Insertion loss | NEXT |
|---|---|---|---|
| 100 MHz | ≥ 20.1 dB | ≤ 19.80 dB | ≥ 44.3 dB |
| 200 MHz | ≥ 18.0 dB | ≤ 28.98 dB | ≥ 39.8 dB |
| 250 MHz | ≥ 17.3 dB | ≤ 32.85 dB | ≥ 38.3 dB |
For the indoor LSZH equivalent, see SF/UTP Cat.6. For 10 Gbps indoors, use S/FTP Cat.6A. Guide: Cat6 vs Cat6A: Which Cable to Choose.